2-3 HEAT operation

˚F
FAN
AM
HEAT
ON/OFF
TEMP
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
TEST RUN
min
SET
RESET
CLOCK
<HEAT operation time chart>
Operation starts by
P O W E R b u t t o n
ON.
ON
Thermostat
OFF
ON
Indoor fan
OFF
ON
Auto vane
OFF
ON
Booster heater
OFF
ON
Compressor
OFF
ON
Power ON lamp
OFF
ON
STAND BY lamp
OFF
w2 Even if the room temperature falls below the set temperature during this period, the compressor will not start until this peri-
od has ended.
<How to operate>
1 Press POWER ON/OFF button.
2 Press the MODE button to display "HEAT"
3 Press the TEMP(
NOTE: The set temperature changes 2°F when the TEMP(
<Display in HEAT operation>
[DEFROST]
The [DEFROST] symbol is only displayed during the defrost operation.
[STANDBY]
The [STANDBY] symbol is only displayed from the time the heating
operation starts until the heated air begins to blow.
Room temperature
becomes equal to
set temperature.
LOW w1
LOW w1
LOW or HIGH
Depends on remote
controller setting
Horizontal
Hot adjustment
Minimum 3 minutes w2
From POWER ON until
warm begins to blow
or
) button to set the desired temperature.
button is pressed one time.
Heating 63 to 83°F.
Room temperature
Operation stops by
falls below set tem-
P O W E R b u t t o n
perature.
OFF.
LOW or HIGH
Depends on remote
controller setting
Horizontal
Hot adjustment
31
or
).
w1 Changeable LOW or HIGH
by indoor dip switch SW1- 6 .
OFF during thermostat OFF
hot adjustment
defrosting