2-5 Auto vane control
˚F
AUTO
FAN
SWING
AM
ON/OFF
TEMP
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
TEST RUN
min
SET
RESET
CLOCK
<Remote controller display>
Changes by pressing the AIR DISCHARGE button.
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the discharge direction in automatically set to 10°. After, it can be changed to
another direction with VANE (
<Auto return>
When discharge 60° or 70° continues for 1 hour with the fan speed at LOW, the discharge direction turns to the horizontal
discharge automatically.
After that, 60° or 70° is available by setting with the remote controller, and it continues for 1 hour.
If the discharge direction changes from 60° or 70°, the direction returns to the horizontal discharge when 1 hour has
passed since the discharge 60° started.
If the discharge direction changes from 60° (or 70°) to the horizontal discharge, the 1-hour timer to return the horizontal
discharge is cancelled.
(2) HEAT operation
At the start-up of HEAT operation, discharge direction depends on the setting of the last operation.
After, it can be changed to another direction with VANE (
the remote controller settings under any of the following conditions.
Thermostat OFF
Defrosting
Indoor fan speed LOW in hot adjustment
1
10°
2
30° downward
3
60° downward
4
70° downward
5
SWING
) button on the remote controller.
<How to operate>
To change the air flow direction, press VANE (
1
2
30˚
10˚
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from LOW to HIGH during 30°
downward discharge in COOL mode, the direction auto-
matically changes to 10°.
) button. The discharge direction shifts to 10° regardless of
35
4
3
70˚
60˚
) button.
5
SWING