free hit counter
Daikin FCQ18PVJU Engineeiring Data

Daikin FCQ18PVJU Engineeiring Data

Split system air conditioners skyair inverter
Hide thumbs Also See for FCQ18PVJU:

Advertisement

EDSUSE28-956S
Split System Air Conditioners
SkyAir Inverter
RZQ-P, M series
— Heat pump —

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FCQ18PVJU

  • Page 1 EDSUSE28-956S Split System Air Conditioners SkyAir Inverter RZQ-P, M series — Heat pump —...
  • Page 2: Table Of Contents

    EDSUSE28-956S Part 1 RZQ-P, M series — Heat pump — .......... 1 1. External appearance ...................3 1.1 Indoor unit ....................3 1.2 Outdoor unit....................4 2. Model name, power supply and nomenclature ...........5 2.1 Model name and power supply ..............5 2.2 Nomenclature ....................
  • Page 3 EDSUSE28-956S Part 2 Available Options ..............57 1. Accessories....................58 1.1 Indoor unit ....................58 1.2 Outdoor unit....................58 NOTE: For detail of Installation and Operation of these sytems, refer to the applicable installation and operation instructions as supplied with the equipment. Table of contents...
  • Page 4: Part 1 Rzq-P, M Series - Heat Pump

    EDSUSE28-956S Part 1 RZQ-P, M series — Heat pump — Model series Class Power supply Indoor unit — — — Outdoor unit 1. External appearance ...................3 1.1 Indoor unit ....................3 1.2 Outdoor unit....................4 2. Model name, power supply and nomenclature ...........5 2.1 Model name and power supply ..............
  • Page 5 EDSUSE28-956S 8. Safety devices list ..................40 8.1 FCQ......................40 8.2 FHQ......................41 8.3 FAQ ......................42 9. Capacity tables ..................43 9.1 FCQ......................43 9.2 FHQ......................46 9.3 FAQ ......................49 9.4 Capacity correction ratio................50 10.Operation limits ..................52 11.Center of Gravity ..................54 11.1 Indoor unit ....................
  • Page 6: Edsuse28-956S

    EDSUSE28-956S External appearance External appearance Indoor unit Ceiling-mounted cassette type (Multi flow) FCQ18PVJU FCQ24PVJU FCQ30PVJU FCQ36MVJU FCQ42MVJU Ceiling-suspended type FHQ18PVJU FHQ24PVJU FHQ30PVJU FHQ36MVJU FHQ42MVJU Wall-mounted type FAQ18PVJU FAQ24PVJU RZQ-P, M series...
  • Page 7: Outdoor Unit

    External appearance EDSUSE28-956S Outdoor unit RZQ18PVJU RZQ24PVJU RZQ30PVJU RZQ36MVJU RZQ42MVJU RZQ-P, M series...
  • Page 8: Model Name, Power Supply And Nomenclature

    EDSUSE28-956S Model name, power supply and nomenclature 2. Model name, power supply and nomenclature Model name and power supply Indoor unit Outdoor unit Power supply FCQ18PVJU* RZQ18PVJU* FCQ24PVJU* RZQ24PVJU* Ceiling-mounted cassette type FCQ30PVJU* RZQ30PVJU* (Multi-flow) FCQ36MVJU RZQ36MVJU FCQ42MVJU RZQ42MVJU FHQ18PVJU*...
  • Page 9: Specifications

    Specifications EDSUSE28-956S 3. Specifications Ceiling-mounted cassette type (Multi-flow) Indoor unit FCQ18PVJU FCQ24PVJU FCQ30PVJU Model Outdoor unit RZQ18PVJU RZQ24PVJU RZQ30PVJU Power supply 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V Cooling capacity Btu/h 18,000 24,000 30,000 Heating capacity...
  • Page 10 EDSUSE28-956S Specifications Ceiling-mounted cassette type (Multi-flow), continued Indoor unit FCQ36MVJU FCQ42MVJU Model Outdoor unit RZQ36MVJU RZQ42MVJU Power supply 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V Cooling capacity Btu/h 36,000 40,500 Heating capacity Btu/h 39,500 41,500 Indoor unit FCQ36MVJU FCQ36MVJU 11–3/8 ×...
  • Page 11: Fhq

    Specifications EDSUSE28-956S Ceiling-suspended type Indoor unit FHQ18PVJU FHQ24PVJU FHQ30PVJU Model Outdoor unit RZQ18PVJU RZQ24PVJU RZQ30PVJU Power supply 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V Cooling capacity Btu/h 18,000 24,000 30,000 Heating capacity Btu/h 20,000 27,000 34,000 Indoor unit FHQ18PVJU...
  • Page 12 EDSUSE28-956S Specifications Ceiling-suspended type, continued Indoor unit FHQ36MVJU FHQ42MVJU Model Outdoor unit RZQ36MVJU RZQ42MVJU Power supply 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V Cooling capacity Btu/h 36,000 40,500 Heating capacity Btu/h 37,500 39,500 Indoor unit FHQ36MVJU FHQ42MVJU Color White (10Y9/0.5) White (10Y9/0.5) Dimensions H×W×D...
  • Page 13: Faq

    Specifications EDSUSE28-956S Wall-mounted type Indoor unit FAQ18PVJU FAQ24PVJU Model Outdoor unit RZQ18PVJU RZQ24PVJU Power supply 1 phase 60Hz 208-230V 1 phase 60Hz 208-230V Cooling capacity Btu/h 18,000 24,000 Heating capacity Btu/h 20,000 26,000 Indoor unit FAQ18PVJU FAQ24PVJU Color White (3.0Y8.5/0.5) White (3.0Y8.5/0.5) Dimensions H×W×D...
  • Page 14: Dimensions And Service Space

    EDSUSE28-956S Dimensions and service space 4. Dimensions and service space Indoor unit 4.1.1 FCQ (Ceiling-mounted cassette type) FCQ18PVJU / FCQ24PVJU / FCQ30PVJU FCQ36MVJU / FCQ42MVJU RZQ-P, M series...
  • Page 15 Dimensions and service space EDSUSE28-956S 4.1.2 FHQ (Ceiling-suspended type) FHQ18PVJU / FHQ24PVJU / FHQ30PVJU FHQ36MVJU / FHQ42MVJU RZQ-P, M series...
  • Page 16 EDSUSE28-956S Dimensions and service space 4.1.3 FAQ (Wall-mounted type) FAQ18PVJU / FAQ24PVJU RZQ-P, M series...
  • Page 17: Wired Remote Controller

    Dimensions and service space EDSUSE28-956S Wired remote controller BRC1D71 RZQ-P, M series...
  • Page 18: Wireless Remote Controller

    EDSUSE28-956S Dimensions and service space Wireless remote controller BRC7C812 (for FCQ) RZQ-P, M series...
  • Page 19 Dimensions and service space EDSUSE28-956S BRC7E83 (for FHQ) RZQ-P, M series...
  • Page 20 EDSUSE28-956S Dimensions and service space BRC7E818 (for FAQ) RZQ-P, M series...
  • Page 21: Outdoor Unit

    Dimensions and service space EDSUSE28-956S Outdoor unit RZQ18PVJU / RZQ24PVJU / RZQ30PVJU RZQ-P, M series...
  • Page 22 EDSUSE28-956S Dimensions and service space RZQ36MVJU / RZQ42MVJU RZQ-P, M series...
  • Page 23: Installation Service Space

    Dimensions and service space EDSUSE28-956S Installation service space RZQ18PVJU / RZQ24PVJU / RZQ30PVJU 3D064213 RZQ-P, M series...
  • Page 24 EDSUSE28-956S Dimensions and service space 3D064213 RZQ-P, M series...
  • Page 25 Dimensions and service space EDSUSE28-956S 3D064213 RZQ-P, M series...
  • Page 26 EDSUSE28-956S Dimensions and service space RZQ36MVJU / RZQ42MVJU 3D047381 RZQ-P, M series...
  • Page 27 Dimensions and service space EDSUSE28-956S 3D047381 RZQ-P, M series...
  • Page 28: Piping Diagrams

    EDSUSE28-956S Piping diagrams 5. Piping diagrams Indoor unit + Outdoor unit FCQ18PVJU / FHQ18PVJU / FAQ18PVJU + RZQ18PVJU FCQ24PVJU / FHQ24PVJU / FAQ24PVJU + RZQ24PVJU FCQ30PVJU / FHQ30PVJU + RZQ30PVJU RZQ-P, M series...
  • Page 29: Indoor Unit

    Piping diagrams EDSUSE28-956S Indoor unit FCQ36MVJU / FCQ42MVJU FHQ36MVJU / FHQ42MVJU 4D024460D RZQ-P, M series...
  • Page 30: Outdoor Unit

    EDSUSE28-956S Piping diagrams Outdoor unit RZQ36MVJU / RZQ42MVJU 3D047385 RZQ-P, M series...
  • Page 31: Wiring Diagrams

    Wiring diagrams EDSUSE28-956S 6. Wiring diagrams Indoor unit FCQ18PVJU / FCQ24PVJU / FCQ30PVJU FCQ36MVJU / FCQ42MVJU RZQ-P, M series...
  • Page 32 EDSUSE28-956S Wiring diagrams FHQ18PVJU / FHQ24PVJU / FHQ30PVJU FHQ36MVJU / FHQ42MVJU RZQ-P, M series...
  • Page 33 Wiring diagrams EDSUSE28-956S FAQ18PVJU / FAQ24PVJU RZQ-P, M series...
  • Page 34: Outdoor Unit

    EDSUSE28-956S Wiring diagrams Outdoor unit RZQ18PVJU / RZQ24PVJU / RZQ30PVJU RZQ-P, M series...
  • Page 35 Wiring diagrams EDSUSE28-956S RZQ36MVJU / RZQ42MVJU RZQ-P, M series...
  • Page 36: External Connection Diagram

    EDSUSE28-956S Wiring diagrams External connection diagram RZQ18PVJU / RZQ24PVJU / RZQ30PVJU Notes: 1) All wiring, components, and materials procured on site must comply with all applicable local and national codes. 2) Use copper conductors only. 3) See the Wiring Diagram for wiring details. 4) Install a circuit breaker for safety purposes.
  • Page 37 Wiring diagrams EDSUSE28-956S RZQ36MVJU / RZQ42MVJU Notes: 1) All wiring, components, and materials procured on site must comply with all applicable local and national codes. 2) Use copper conductors only. 3) See the Wiring Diagram for wiring details. 4) Install a circuit breaker for safety purposes. 5) All field wiring and components must be provided by a licensed electrician.
  • Page 38: Electrical Characteristics

    EDSUSE28-956S Electrical characteristics 7. Electrical characteristics Indoor unit FCQ18PVJU / FCQ24PVJU / FCQ30PVJU FCQ36MVJU / FCQ42MVJU 4D042636B RZQ-P, M series...
  • Page 39 Electrical characteristics EDSUSE28-956S FHQ18PVJU / FHQ24PVJU / FHQ30PVJU FHQ36MVJU / FHQ42MVJU 4D049333A RZQ-P, M series...
  • Page 40 EDSUSE28-956S Electrical characteristics FAQ18PVJU / FAQ24PVJU 4D046466B RZQ-P, M series...
  • Page 41: Outdoor Unit

    Electrical characteristics EDSUSE28-956S Outdoor unit RZQ18PVJU / RZQ24PVJU / RZQ30PVJU ground 3D064227A RZQ-P, M series...
  • Page 42 EDSUSE28-956S Electrical characteristics RZQ36MVJU / RZQ42MVJU ground 3D047384 RZQ-P, M series...
  • Page 43: Safety Devices List

    Safety devices list EDSUSE28-956S 8. Safety devices list FCQ18PVJU / FCQ24PVJU / FCQ30PVJU 3D042635B FCQ36MVJU / FCQ42MVJU 3D042635B RZQ-P, M series...
  • Page 44: Fhq

    EDSUSE28-956S Safety devices list FHQ18PVJU / FHQ24PVJU / FHQ30PVJU 3D049334A FHQ36MVJU / FHQ42MVJU 3D049334A RZQ-P, M series...
  • Page 45: Faq

    Safety devices list EDSUSE28-956S FAQ18PVJU / FAQ24PVJU 4D047085B RZQ-P, M series...
  • Page 46: Capacity Tables

    EDSUSE28-956S Capacity tables 9. Capacity tables FCQ18PVJU + RZQ18PVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r Te m p . ° F D B...
  • Page 47 Capacity tables EDSUSE28-956S FCQ30PVJU + RZQ30PVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r Te m p . ° F D B I n d o o r A i r 1 0 4 Te m p .
  • Page 48 EDSUSE28-956S Capacity tables FCQ42MVJU + RZQ42MVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r Te m p . ° F D B I n d o o r A i r 1 0 4 Te m p .
  • Page 49: Fhq

    Capacity tables EDSUSE28-956S FHQ18PVJU + RZQ18PVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r Te m p . ° F D B I n d o o r A i r 1 0 4 Te m p .
  • Page 50 EDSUSE28-956S Capacity tables FHQ30PVJU + RZQ30PVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r Te m p . ° F D B I n d o o r A i r 1 0 4 Te m p .
  • Page 51 Capacity tables EDSUSE28-956S FHQ42MVJU + RZQ42MVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r T e m p . ˚ F D B I n d o o r A i r 1 0 4 T e m p .
  • Page 52: Faq

    EDSUSE28-956S Capacity tables FAQ18PVJU + RZQ18PVJU C o o l i n g C a p a c i t y 2 3 0 V – 6 0 H z O u t d o o r A i r Te m p . ° F D B I n d o o r A i r 1 0 4 Te m p .
  • Page 53: Capacity Correction Ratio

    Capacity tables EDSUSE28-956S Capacity correction ratio RZQ18PVJU / RZQ24PVJU / RZQ30PVJU RZQ-P, M series...
  • Page 54 EDSUSE28-956S Capacity tables RZQ36MVJU / RZQ42MVJU RZQ-P, M series...
  • Page 55: Operation Limits

    Operation limits EDSUSE28-956S 10. Operation limits RZQ18PVJU / RZQ24PVJU / RZQ30PVJU 3D064229 RZQ-P, M series...
  • Page 56 EDSUSE28-956S Operation limits RZQ36MVJU / RZQ42MVJU C : 3D047386 RZQ-P, M series...
  • Page 57: Center Of Gravity

    EDSUSE28-956S 11. Center of gravity 11.1 Indoor unit FCQ18PVJU / FCQ24PVJU / FCQ30PVJU FCQ36MVJU / FCQ42MVJU Unit (in.) 4D042639B RZQ-P, M series...
  • Page 58: Outdoor Unit

    EDSUSE28-956S 11.2 Outdoor unit RZQ18PVJU / RZQ24PVJU / RZQ30PVJU Unit (in.) 4D064214 RZQ-P, M series...
  • Page 59 EDSUSE28-956S RZQ36MVJU / RZQ42MVJU Unit (in.) 4D047387 RZQ-P, M series...
  • Page 60: Part 2 Available Options

    EDSUSE28-956S Part 2 Available Options 1. Accessories....................58 1.1 Indoor unit ....................58 1.2 Outdoor unit....................58 Available Options...
  • Page 61: Accessories

    Accessories EDSUSE28-956S 1. Accessories Indoor unit 1.1.1 Optional accessories (For unit) Model FCQ18PVJU FCQ24PVJU FCQ30PVJU FCQ36MVJU FCQ42MVJU Item Decoration panel BYC125K-W1 High efficiency filter 65% (calorimeter) KAFP556D160 High efficiency filter MERV-12 KAFP557D160 Filter related Filter chamber for above KDDFP55D160 Ultra long life filter...
  • Page 62 Specifications, designs and other content appearing in this brochure are current as of July 2009 but subject to change without notice. EDSUSE28-956S Printed in U.S.A. 7/2009 K FS...

Table of Contents