Table of contents Foreword Introduction and Safety ..................4 Use of the ComfoControl Ease ................. 5 2.1. Time and Date Settings ................6 2.2. Reading and setting the comfort temperature ........... 7 2.3. Reading and setting the ventilation volume ..........7 2.4.
CC Ease for its entire working life. Congratulations, you now own a ComfoControl Ease. We wish you lots of comfort. What is the purpose of this control unit? The ComfoControl Ease - referred to further as the CC Ease - enables users 4 - EN...
2. Use of the ComfoControl Ease The overview below summarizes the information that will be displayed on the CC Ease. Time and date Supply air or exhaust air Automatic (AUTO) ON or OFF or manual ventilation (MANUAL) Geothermal heat exchanger (EWT),...
2.1 Time and date settings If an extractor hood is not 1. Press longer than 2 seconds. registered or is not supported, - Wait until the day, e.g. “Sa”, starts then the Temporary High Setting flashing. will be activated by a short press 2.
2.2 Reading and setting the comfort 2.3 Reading and setting the ventilation temperature volume The comfort temperature can be read, but also set to the desired indoor Reading the ventilation volume temperature. Based on this temperature, The current ventilation volume, e.g. “2”, the ComfoAir will then automatically will always be displayed on the CC Ease.
Setting ventilation levels: 1. Press to increase the ventilation level. 2. Press to decrease the ventilation level. Setting the ventilation levels The ventilation level can also be set manually by setting this higher or lower. A total of 4 ventilation volumes/levels can be set.
While the time delay is still active, a “t” The timer of the temporary high will be displayed instead of the extractor setting can be switched off early hood symbol. by pressing 2.5 Switching the extractor hood on/ off (optional) 1.
Setting A can not be programmed. For 2. Press again (second time) to the remaining settings eight changeovers switch the exhaust fan off (and to per day can be programmed. switch the supply fan on at the same time). The ventilation volume can be changed/ set as follows: 1.
The selected ventilation profile stage will be deleted if ventilation setting “d” is selected here. Setting A can not be programmed. 5. Press - Wait until the hours flash, e.g. “7”. 6. Select the required start time in hours using 11.
Accessing the P menus 1. Press together for 2 seconds. - Wait until P menu “P2” appears on the display. 2. Select the required P menu, e.g. 2, using Return to main screen 9. Press twice to go back. 3. Press 4.
Page 13
Menu P1 ➝ Status of programmes Status Sub-menu Description Activated Is menu 20 currently active? Yes (1) / No (0) Is menu 21 currently active? Yes (1) / No (0) Is menu 22 currently active? Yes (1) / No (0) Is menu 23 currently active? Yes (1) / No (0) Is menu 24 currently active?
Page 14
Values Time delay Sub-menu Description Minimum Maximum Factory reset Deactivation delay for ventilation 0 Min. 120 Min. 0 Min. (Optional) setting 3. ■ If you BRIEFLY engage ventilation Note: setting 3 (<3sec.), the ComfoAir Only applies to systems fitted switches to the HIGH SETTING with a corded 3-position for “x”...
Page 15
Values Time delay Sub-menu Description Minimum Maximum Factory reset Time for the temporary high setting. 0 Min. 120 Min. 30 Min. ■ After pressing and holding (>2 sec.) , the ComfoAir switches to the high setting for “x” minutes and then switches back automatically to the normal ventilation setting.
4. Warranty and liability Liability The CC Ease is designed and manufactured for use with a balanced Warranty conditions ventilation system with heat recovery. Any The CC Ease is covered by a other application is seen as inappropriate manufacturer’s warranty for a period of 24 use and can result in damage to the months after fitting up to a maximum of CC Ease or personal injury, for which the...
Demounting ■ A flashing “A” with a number extension If you need to demount the CC Ease in the field that normally displays the front section, for instance for painting ventilation setting; purposes, then follow the steps below: ■ A flashing “E” with a number extension 1.
Page 18
Meanings of malfunction alerts The internal filters are included in the standard configuration of the ComfoAir. The external filters (optional) form part of Code Description the ducting of the ventilation system, yet NTC sensor Tge is defective. (= Temperature of outdoor air for do not form part of the ComfoAir.