FOllOW InStruCtIOnS MaY reSult In PrOPertY daMage, bOdIlY InjurY, Or even deatH. FOr uSe In tHe u.S. and Canada. tHe OakWOOd IS nOt aPPrOved FOr MObIle HOMe InStallatIOn. IF tHIS HarMan StOve IS nOt PrOPerlY InStalled, a HOuSe FIre MaY reSult. FOr YOur SaFetY, FOllOW InStallatIOn dIreCtIOnS.
Page 3
Please read this entire manual before you install and use your new heating appliance. Failure to follow instructions may result in property damage, bodily injury, or even death. Harman Home Heating 352 Mountain House Road Halifax, PA 17032 U.S.A. Harman Oakwood...
Page 4
Harman Air Wash System. The Harman Oakwood has an ash pan with its own ash door that is used to remove ashes while the stove is in operation. This means you can keep one fire all winter if you desire.
26.235" 18.037" 21" 7.5" 30.234" 21" The Harman Oakwood meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 1990. Weight..........440 lbs Flue Size........6 inch Log Length Recommended...21" Max Heating Capacity......2,000 sq. ft. Average Emissions.......2.32 Grams Per Hr.
Page 6
SPeCIFICatIOnS Top Load Door Optional Cooking Grill Top Load Opening Bypass Damper Control Handle Front Load Door Grate Andirons Front Load Door Latch Air Control Ash Door Ash Door Latch Harman Oakwood...
(See instructions in the Maintenance section.) Grates The Harman Oakwood's unique grate system consists SaFetY nOtICe of one flat bottom grate, and two front andirons. The bot- I F T H I S A P P L I A N C E I S N O T...
The Combustion Process Two important controls - the damper bypass handle and the air control lever regulate the operation and output of the Combustion in the Harman Oakwood is precisely con- stove. trolled and is best explained in two parts. To open the top or front loading door, you must open During a wood fire, combustion air enters at the bottom the damper bypass, or smoke will come in the room.
If, after five minutes of burning with the damper closed, smoke is visible coming from the chimney, you probably do not have the proper coal bed. Open the bypass damper and continue with the process until a significant coal bed is formed. Harman Oakwood 9...
Page 10
As you begin to operate your stove at higher tem- peratures, you will notice a “hot” or unpleasant smell; this is just the paint going through the curing process, and will disappear after a few fires. Harman Oakwood...
A corner installation is one in which the back of the stove is positioned diagonally across a corner of the room. Each installation requires its own set of clearances. Harman Oakwood...
Page 12
InStallatIOn/ClearanCeS 21" 25" Harman Oakwood See NFPA 211 for more installation clearance reductions when using USM wall protection, etc.
Page 13
InStallatIOn/ClearanCeS See NFPA 211 for more installation clearance reductions when using USM wall protection, etc. Harman Oakwood...
Page 14
InStallatIOn/ClearanCeS Harman Oakwood See NFPA 211 for more installation clearance reductions when using USM wall protection, etc.
Page 15
The Oakwood, bypass control and the top load door operation is not compromised or unsafe. (See above illustration.) loaded with wood weighs approximately 500 pounds (250kg). Installing in front of a fireplace with Mantel non- Combustible Combustible material fireplace 22" 16" Harman Oakwood...
3/8" (9 mm) wall thickness must run The Harman Oakwood may be installed with a mini- through the brick wall to the chimney liner (but not be- mum (.6 mm) 24 gauge chimney connector pipe. The size yond the inner surface of the liner).
10 ft (3 m) radius of the top of the chimney. Thus, the 2 foot, 3 foot, 10 foot rule; "The top of the chimney must be a minimum of 3 feet above where it exits the roof, and 2 feet higher than anything within 10 feet." Harman Oakwood...
Page 18
The chimney con- nector must enter the chimney at a place where it is lined, and the fireplace must be made inoperable. For example, you might remove the damper, replacing it with a secure, Harman Oakwood...
Page 19
Other causes of poor ventilation or draft are icing, exhaust fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occa- sional odor, check these possibilities and increase the air flow in your home. Harman Oakwood...
Collar Chimney Sections Chimney Cap Roof Flashing roof radiation roof Factory-Built shield radiation metal Chimney shield attic sealed storm Collar radiation Roof Flashing shield Cathedral style Chimney support minimum air space Chimney with Chimney Listing Finishing Col- support Chimney Con- nector Chimney Connector Harman Oakwood...
Page 21
Flue liner with re- quired air space Three Sheet Metal Screws airtight per Joint of Chimney insulated Connector Clean-out mantel and trim pro- tection Damper Closed and sealed with Non-Combus- tible Material. Floor protection* Combustible Floor * Floor protection in accordance with Solid Fuel Appliance Listing Harman Oakwood...
Page 22
Oakwood to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection) Flue liner with re- airtight quired air space insulated Clean-Out Stainless Steel Chimney Connector Must Extend to Flue liner Minimum 8" Masonry Thickness in Front of smoke Chamber Use Damper Adapter or Seal with Non-Combustible Material Damper Plate is Removed or Fastened in Open Posi- tion Listed Fireplace Trim protection for re- duced Clearance Floor protection* Combustible Floor *Floor Protection in Accordance with Solid Fuel Appliance Listing Harman Oakwood...
Page 23
Full Relining Fireplace Conversion: Freestanding Appliance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner manufacturer's instructions on insulation and support UL1777 Insulated Stainless Steel Flex liner or Other approved lin- ing System in Offsets. Listed Fireplace Trim Protection for reduced Clearance Damper Plate Removed or Fas- tened in Open Position Use Damper Adapter or Seal with Non-Combus- tible material Floor protection* Combustible Floor *Floor Protection in Accordance with Solid Fuel Appliance Listing Harman Oakwood...
Page 24
Flue liner with required air space Listed or Approved Thimble Assembly Combustible 1" Clearance for Complex- Wall ity Exterior Chimney 2" Clearance for Interior sheetrock airtight Chimney and 2" Clear- insulated ance for NFPA 211-Type Clean-out Approved Thimbles mantel & trim protection Damper Closed and sealed with Non- Combustible Material. Floor protection* Combustible Floor * Floor Protection in Accordance with Solid Fuel Appliance Listing ** Check with your local building codes for clearance. Harman Oakwood...
If any bricks have been damaged, replace them with Harman or brush damage and diverts most of the removed materials into the firebox for easy clean-up and removal. Once the replacement parts.
Gaskets are used at strategic positions when building the When wood is burned slowly, it produces tar and Harman Oakwood for controlling the path that incoming other organic vapors, as well as soot, which combine with and outgoing air and gases take through the stove. You expelled moisture to form creosote .
Page 27
Cozy screen of combustion air. The air supply must originate outside Your Harman Oakwood can be burned like a fireplace the dwelling and be screened to keep out debris, birds with the optional Cozy Screen. The Cozy Screen can be or animals.
Page 28
Oakwood Service Parts beginning Manufacturing date: n/a Cast Iron Stove ending Manufacturing date: active 1-90-02490-1 (black), 1-90-02490-2 (Charcoal), 1-90-02490-3 (goldenfi re), 1-90-02490-4 (Metallic blue), 1-90-02490-5 (Honey glo), 1-90-02490-10 (Mojave red), 1-90-02490-12 (Forest green) Part number list on following page. 10/10...
Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. at depot IteM deSCrIPtIOn...
Page 30
Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. atdepot IteM deSCrIPtIOn...
Page 31
Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. at depot IteM deSCrIPtIOn...